Agilent 7890B GC with 5977A MSD, 7697A Headspace and Autosampler




Includes:

  • Agilent 7890B GC with 5977A MSD, 7697A Headspace and Autosampler
    • Agilent 7890B
      • Dual split/splitless (S/S) inlet
    • Agilent 5977A MSD
      • 111 Sample
    • Agilent 7693 Autosampler
      • Tray
      • Tower
    • Roughing Pump
    • Data System
    • Warranty Coverage

Options:

  • Workbench
  • Wiley Registry 12th Edition / NIST 2020 Mass Spectral Library
  • Installation & Familiarization
  • Extended Warranty


This Agilent 7890B GC with 5977A MSD, 7697A Headspace and Autosampler comes fully refurbished by Conquer Scientific.

The Agilent 7890B stands as a pinnacle in gas chromatography (GC), delivering unparalleled performance across all GC applications through advanced electronic pneumatic control (EPC) modules and precise temperature regulation within its high-performance GC oven.

The Agilent 5977 Series MSD serves as an independent capillary GC detector designed for compatibility with Agilent gas chromatographs.

The Agilent 7697A Headspace Sampler is a gas chromatography (GC) sampling instrument utilizing an inert sample pathway to efficiently transfer volatile compounds from a sample matrix to a GC or GC/MS system. Leveraging the technology of the 7890 GC and 7693A automatic liquid sampler, it is meticulously crafted to exceed the demands of rigorous laboratory settings.

Agilent 7890B Features: 

  • Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
  • Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimensional gas chromatography (GC-GC/Deans switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
  • Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
  • Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
  • Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
  • Helium conservation module and alternative carrier gas solutions dramatically reduce the amount of helium used to offer flexibility and cost savings for your laboratory.

Agilent 5977 MSD Features: 

  • Local control panel (LCP) for locally monitoring and operating the MSD
  • One of two different high vacuum pumps
  • One of three different foreline pumps
  • Four different types of independently MSD heated electron-ionization (EI)
    sources available: standard (stainless), inert, extraction (XTR), and high
    efficiency (HES)
  • Optional chemical ionization (PCI/NCI) modes are available that add a
    chemical-ionization (CI) source, reagent gas flow controller and plumbing,
    and CI tuning calibration
  •  Independently MSD-heated hyperbolic quadrupole mass filter
  • High-energy dynode (HED) electron multiplier detector
  • Independently GC-heated GC/MSD interface

Agilent 7697A Features: 

  • The 7697A Headspace Sampler 12-vial capacity configuration is perfect for academic labs and those with small sample loads
  • Standard 111 sample configuration with three priority samples
  • Trays can be exchanged during a sequence for increased sample capacity
  • Hydrogen carrier and auto sleep/wake modes conserve valuable laboratory resources
  • Independent control of vial pressurization and column head pressure provides increased precision by ensuring no back pressure during sample transfer
  • Automatic vial leak test checks each vial during pressurization – without time-consuming calibration – to ensure that every sample is properly capped
  • Sample bar code reader with data transfer capabilities allows you to track samples before they enter the oven
  • Multiple headspace concentrations (MHC) with up to 100 extractions per GC start allows for more complete sampling and increased sensitivity
  • Multiple headspace extractions (MHE) with up to 100 extractions per vial
  • Supports 10-mL, 20-mL, or 22-mL vials without an adapter
  • Samples depressurize before returning to the tray
  • Transfer line interface accessory allows a headspace sampler and ALS to connect to the same inlet on the GC
Model

7890A / 5977A / 7697A / 7693

Condition

Refurbished

OEM

Agilent Technologies

Founded by a scientist, with the needs of scientists in mind, Conquer Scientific has supported laboratories with quality pre-owned laboratory equipment at an affordable cost since 2003. With Conquer you can also expect expert service and support, along with installation, training, and trade-in options. From general lab equipment such as centrifuges and balances, to analytical instrumentation such as HPLC, IC, GC and MS systems, Conquer offers options to keep your laboratory running efficiently.

Looking for replacement parts and consumables? Visit our Chromatography Parts website at www.ChromatographyParts.com.