Waters Acquity UPLC I-Class Sample Manager FTN-I

$14,900
Manufacturer: Waters Model: UPLC I-Class Sample Manager FTN-I Condition: Used Warranty: 30 day (90 day with onsite installation purchase.) Test Performed: Listing ID# 41493

This is a Pre-owned Waters Acquity UPLC I-Class Sample Manager FTN-I.

System Includes:
  • Waters Acquity UPLC I-Class Sample Manager FTN-I
  • Cables and connectors

ACQUITY UPLC I-Class PLUS System (SM-FTN-I)

The Waters ACQUITY UPLC I-Class PLUS System’s holistic design is targeted for investigative analysis where maximized peak capacity, throughput, and sensitivity are critical and is perfectly suited for running any MS-based applications. The system is comprised of a Binary Solvent Manager (BSM) and a Sample Manager with Flow-Through Needle (SM-FTN-I); this configuration offers excellent carryover performance.


THE IDEAL INLET TO MASS SPECTROMETRY

The ACQUITY UPLC I-Class PLUS System is designed specifically for the rapid pace of laboratories on the cutting edge of research where LC-MS plays a critical role:

  • Narrow peak widths not only provide enhanced resolution, but also more efficient ionization, enhancing mass spectrometry sensitivity
  • Ultra low delay volume results in exceptionally fast analysis times
  • Sensitivity is enhanced through industry-leading carryover performance
  • Multidimensional UPLC configurations lead to improved sample characterization through selective isolation

The ACQUITY UPLC I-Class PLUS System is designed to be the ideal inlet to mass spectrometry, maximizing the analytical value of each and every analysis. With the ability to achieve high resolution and high sensitivity methods rapidly, the answer you seek is not only obtained very quickly, but with new levels of clarity to enhance the characterization of even the most complex samples.


Note: Licenses for Waters’ software products are not transferable. Any customer who purchases Waters products are advised that in order to hold a valid license to use the Waters’ software, they must purchase a license and appropriate Application Manager directly from Waters.

SAMPLE MANAGER-FTN (SM-FTN)

Injection volume range

0.1 to 10.0 μL as standard configuration
Up to 1000.0 μL with optional extension loop

Accuracy

±0.2 μL, measured by fluid weight removed from vial with 10.0 μL injections averaged over
20 injections using standard 100-μL syringe

Injection linearity

0.999 (See ACQUITY UPLC I-Class System Specifications document for conditions)

Sample manager precision

<1% area RSD 0.2 to 1.9 µL injection
<0.5% area RSD 2 to 10 µL injection
(See ACQUITY UPLC I-Class System Specifications document for conditions)

Maximum sample capacity

Any two of the following:
• 96 and 384 microtiter plates
• 48 position 2.00-mL vial plates
• 48 position 0.65-mL micro-centrifuge tube plates
• 24 position 1.50-mL micro-centrifuge tube plates

Sample compartment temperature range

4.0 to 40.0 °C, settable in 0.1 °C increments; maintains 19 °C below ambient with a tolerance
range between -2 and +4 °C

Temperature accuracy

±0.5 °C at sensor (See ACQUITY UPLC I-Class Systems Specification Guide for conditions)

Temperature stability

±1.0 °C at sensor (See ACQUITY UPLC I-Class Systems Specification Guide for conditions)

Injection needle wash

Integrated, active, programmable

Minimum sample required

3 μL residual, using Waters’ total recovery 2-mL vials (zero offset)

Carryover (UV)

<0.004%
<0.001% typical
(See ACQUITY UPLC I-Class System Specifications document for conditions)

Advanced sample manager capabilities

Auto-dilution and auto-addition

Primary wetted materials

316L stainless steel, polyimide, PEEK blend, DLC, PPS