Thermo Electron Dionex Surveyor MSQ Plus Single Quadrupole Mass Spectrometer

$2,900
Manufacturer: Thermo Electron Model: DIONEX Surveyor MSQ Plus MS Condition: Used Warranty: AS-IS Test Performed: Power Test Listing ID# 24078

Thermo Electron Dionex Surveyor MSQ Plus Single Quadrupole Mass Spectrometer


The MSQ Plus Mass Spectrometer can be used in a wide range of applications and methodologies in both HPLC and IC. Only 12 inches wide, the MSQ Plus is by far the most compact mass spectrometer on the market today. It provides universal detection and characterization of analytes in the 17–2000 m/z range.

The MSQ Plus features a newly designed self-cleaning Atmospheric Pressure Ionization (API) source for outstanding sensitivity and noise reduction. Compatible with existing LC and IC methods, the MSQ Plus is more sensitive, rugged, powerful, easier to use, and smaller than any other instrument of its kind.

  • New M Path source design virtually eliminates neutral noise and background
  • Unique FastLoc probes provide simple and rapid changes for both ESI and APCI modes
  • All features fully supported in Chromeleon® Chromatography Management software
  • Full scan and Selected Ion Monitoring allow rapid screen and target compound analysis
  • Quadrupole analyzer maximizes resolution and provides high stability and minimal drift
  • Enhanced low-mass response for analytes below 60 m/z
  • All new Ion Bright detector system eliminates neutral noise, extending the dynamic range
  • Advanced autotuning wizard includes full system optimization and mass scale calibration

The MSQ Plus features a high-sensitivity, self-cleaning ESI/APCI ionization source that requires no mechanical adjustment or electrostatic focusing for sample optimization. The compact source design is optimized for a wide range of flow rates and supports a wide range of chromatographic buffers.

Note: Sensitivity specifications below are based on loop injections at a flow of 1 mL/min in SIM mode. Noise is RMS after appropriate smoothing.


MSQ Plus Mass Spectrometer Detector Specifications:
Power Requirements 230 V ac one switched power outlet (Rotary Pump and MSQ)
230 or 115 V ac (as required) for PC and monitor and additional hardware
Gas Requirements MSQ Plus requires a supply of high-purity (>99%) nitrogen capable of supplying 12 L/min at 75 psi (5 bar)
Dimensions
(h × w × d)
530 × 300 × 710 mm (21 × 12 × 28 in.)
Weight 60 kg (132 lb)
Ionization modes
(supplied as standard)
Electrospray (ESI)
Atmospheric Pressure Chemical Ionization (APCI)
Range 17–2000 m/z with unit mass resolution
Sensitivity Sensitivity specifications are performed using loop injections at a flow of 1 mL/min in SIM mode. Noise is defined as RMS after appropriate smoothing.
Positive ion ESI—50 pg injection (10 µL × 5 pg/µL) of erythromycin: 1000:1 S/N
Negative ion ESI—20 pg loop injection (10 µL × 2 pg/µL) of p-nitrophenol: 500:1 S/N
Positive ion APCI—50 pg injection (10 µL × 5 pg/µL) of erythromycin: 200:1 S/N
Negative ion APCI—20 pg injection (10 µL × 2 pg/µL) of p-nitrophenol: